Wood Structures and Mitek present:
THE STABILIZER™ TRUSS BRACING SYSTEM
   
    MiTek® Industries introduces a revolutionary new product for the truss industry, The Stabilizer™ truss bracing system provides truss installers the best of both worlds... accurate 24" o.c. truss spacing with ample structural properties for both construction bracing and permanent lateral bracing. The Stabilizer is truly a breakthrough product! Its unique design means truss setting will never be faster, or easier. Just attach The Stabilizer to the top chord of an installed truss, bring up the next truss, and hammer down the top and side tabs. Simple. No cutting and handling spacer blocks or "layout sticks". No fumbling for nails hanging 30 feet in the air! And, since The Stabilizer is inplane you just deck right over the top of it. In addition, the unique structural quality of The Stabilizer allows it to be used as permanent lateral bracing. The Stabilizer is so quick to install, you can brace webs as you set trusses, eliminating the need to return later to install lateral bracing.

To use The Stabilizer on your next truss installation, call your friends at
Wood Structures today! 1-800-341-9612
 

THE STABILIZER™ TRUSS BRACING SYSTEM
Installation Guide and Product Specification

The Stabilizer Truss Bracing System provides temporary construction bracing in the roof and ceiling planes, as well as permanent lateral bracing for webs as specified by your truss engineering. Web forces are not to exceed 8000 lbs. 

    The Stabilizer™ is easily installed by embedding the patented MII 20 teeth on top flap straight into the edge of the truss member to be braced with a framing hammer. The side tabs are then secured by driving the teeth into the face of the truss member being braced.

  • Use The Stabilizer for standard 24" o.c.spacing. For odd spacing, cut and insert a solid block between the trusses.
  • Typically, The Stabilizer is installed at 6'-8' centers along the roof plane and 10'-15' along the ceiling plane. Refer to engineering specificaiton HIB-91, or DSB-89 (published by The Truss Plate Institute) for specific bracing requirement.
  • The Stabilizer must be supplemented with diagonal bracing in the roof and ceiling planes and cross bracing in the web plane at required intervals.

Steel

ASTM A653 Grade 40
0.036 inch (20ga.) Thickness
G60 Galvanized Coating
0.83 lb./piece product weight

Ultimate Capacities**

Compression = 1040 lbs.
Tension = 340 lbs.
Centerline Moment = 1920 in.-lbs.
End Moment = 432 in.-lbs.
** Apply appropriate safety factors

 


IMPORTANT:
The erection contractor is responsible for determining and installing the temporary bracing for the structure, including the trusses. It is most important for the installer to provide adequate means for bracing the first truss installed. The performance of the entire bracing system depends on the adequacy of the ground bracing or other means of bracing the first group of trusses installed. The building designer is responsible for the permanent bracing design of the overall structure including the truss. This includes the design of required supplemental diagonal and cross bracing.